Значение автоматизированной антенатальной кардиотокографии для оценки функцонального состояния плодов, имеющих задержку развития

Research output: Contribution to journalArticlepeer-review

Abstract

Application in obstetric practice of automated antenatal cardiotography method allows to eliminate subjectivity and to raise reliability of fetus condition estimation in group of pregnant woman of high obstetric and perinatal risk. It is established that in group of pregnant women with high risk of fetus condition infringement at cardiotocography dynamic supervision reveal already in II trimester. Herewith the earliest and authentic indicators of fetus condition infringement are: decrease variability basal rhythm fetal heart rate, absence of high variability or prevalence episodes of low variability over high, value of STV-short variability indicators less than 4.0. The obtained data allows to recommend application automated antenatal cardiotocography method in group of pregnant women with high perinatal risk for early diagnostics of fetus functional condition infringement. Possibility to estimate severity level of fetus metabolic acidosis will allow to solve in time issues of optimal obstetric tactics in pregnancy conducting, term and a method of delivery at this category of pregnant women
Original languageEnglish
JournalJournal of Obstetrics and Women's Diseases
Publication statusPublished - Apr 2012

Fingerprint

Dive into the research topics of 'Значение автоматизированной антенатальной кардиотокографии для оценки функцонального состояния плодов, имеющих задержку развития'. Together they form a unique fingerprint.