A study of wake potentials for the pick-ups in storage ring

M. Shafiee, H. Behnamian, S. A.H. Feghhi

Research output: Contribution to journalArticle

Abstract

Calculating wake potentials in accelerators are necessary in order to optimize the accelerator performance in terms of stored current and emittance. Wake potentials due to pick-ups can be an important source for current and emittance degradation. In this paper, we present theoretical analysis and computer simulations of the wake potentials for the beam pipe with and without mounted pick-ups. We introduce generalized wake potential to calculate the transverse wake-field and analyze the effect of pick-ups on these potentials. In addition, the effects of wake potentials due to pick-ups on the bunch length and emittance are studied using ELEGANT particle tracking code.

Original languageEnglish
Article numberT12006
JournalJournal of Instrumentation
Volume12
Issue number12
DOIs
Publication statusPublished - Dec 27 2017
Externally publishedYes

Fingerprint

Storage rings
Pickups
Wake
wakes
Ring
emittance
Accelerator
Particle accelerators
accelerators
Particle Tracking
Theoretical Analysis
Degradation
Transverse
Computer Simulation
computerized simulation
Optimise
Pipe
degradation
Calculate
Necessary

Keywords

  • Accelerator modelling and simulations (multi-particle dynamics; single-particle dynamics)
  • Accelerator Subsystems and Technologies
  • Instrumentation for particle accelerators and storage rings-high energy (linear accelerators, synchrotrons)
  • Instrumentation for synchrotron radiation accelerators

ASJC Scopus subject areas

  • Instrumentation
  • Mathematical Physics

Cite this

A study of wake potentials for the pick-ups in storage ring. / Shafiee, M.; Behnamian, H.; Feghhi, S. A.H.

In: Journal of Instrumentation, Vol. 12, No. 12, T12006, 27.12.2017.

Research output: Contribution to journalArticle

Shafiee, M. ; Behnamian, H. ; Feghhi, S. A.H. / A study of wake potentials for the pick-ups in storage ring. In: Journal of Instrumentation. 2017 ; Vol. 12, No. 12.
@article{50e217f0382849e28335d63f26024ca0,
title = "A study of wake potentials for the pick-ups in storage ring",
abstract = "Calculating wake potentials in accelerators are necessary in order to optimize the accelerator performance in terms of stored current and emittance. Wake potentials due to pick-ups can be an important source for current and emittance degradation. In this paper, we present theoretical analysis and computer simulations of the wake potentials for the beam pipe with and without mounted pick-ups. We introduce generalized wake potential to calculate the transverse wake-field and analyze the effect of pick-ups on these potentials. In addition, the effects of wake potentials due to pick-ups on the bunch length and emittance are studied using ELEGANT particle tracking code.",
keywords = "Accelerator modelling and simulations (multi-particle dynamics; single-particle dynamics), Accelerator Subsystems and Technologies, Instrumentation for particle accelerators and storage rings-high energy (linear accelerators, synchrotrons), Instrumentation for synchrotron radiation accelerators",
author = "M. Shafiee and H. Behnamian and Feghhi, {S. A.H.}",
year = "2017",
month = "12",
day = "27",
doi = "10.1088/1748-0221/12/12/T12006",
language = "English",
volume = "12",
journal = "Journal of Instrumentation",
issn = "1748-0221",
publisher = "IOP Publishing Ltd.",
number = "12",

}

TY - JOUR

T1 - A study of wake potentials for the pick-ups in storage ring

AU - Shafiee, M.

AU - Behnamian, H.

AU - Feghhi, S. A.H.

PY - 2017/12/27

Y1 - 2017/12/27

N2 - Calculating wake potentials in accelerators are necessary in order to optimize the accelerator performance in terms of stored current and emittance. Wake potentials due to pick-ups can be an important source for current and emittance degradation. In this paper, we present theoretical analysis and computer simulations of the wake potentials for the beam pipe with and without mounted pick-ups. We introduce generalized wake potential to calculate the transverse wake-field and analyze the effect of pick-ups on these potentials. In addition, the effects of wake potentials due to pick-ups on the bunch length and emittance are studied using ELEGANT particle tracking code.

AB - Calculating wake potentials in accelerators are necessary in order to optimize the accelerator performance in terms of stored current and emittance. Wake potentials due to pick-ups can be an important source for current and emittance degradation. In this paper, we present theoretical analysis and computer simulations of the wake potentials for the beam pipe with and without mounted pick-ups. We introduce generalized wake potential to calculate the transverse wake-field and analyze the effect of pick-ups on these potentials. In addition, the effects of wake potentials due to pick-ups on the bunch length and emittance are studied using ELEGANT particle tracking code.

KW - Accelerator modelling and simulations (multi-particle dynamics; single-particle dynamics)

KW - Accelerator Subsystems and Technologies

KW - Instrumentation for particle accelerators and storage rings-high energy (linear accelerators, synchrotrons)

KW - Instrumentation for synchrotron radiation accelerators

UR - http://www.scopus.com/inward/record.url?scp=85039772005&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85039772005&partnerID=8YFLogxK

U2 - 10.1088/1748-0221/12/12/T12006

DO - 10.1088/1748-0221/12/12/T12006

M3 - Article

VL - 12

JO - Journal of Instrumentation

JF - Journal of Instrumentation

SN - 1748-0221

IS - 12

M1 - T12006

ER -