All-diode-laser based, dual-cavity AgGaS2 difference-frequency spectrometer for the 9-11 μm range

T. Kaing, D. Lee, J. J. Zondy

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

We report on preliminary performance of a mid-IR doubly-resonant difference frequency (DFG) spectrometer generating 30 nW of 10.2-μm tunable radiation out of 7 mW and 275 mW of the diode laser pump inputs at 778 nm and 842 nm.

Original languageEnglish
Title of host publicationCPEM Digest (Conference on Precision Electromagnetic Measurements)
EditorsT.L. Nelson
PublisherIEEE
Pages157-158
Number of pages2
Publication statusPublished - 1998
Externally publishedYes
EventProceedings of the 1998 Conference Precision Electromagnetic Measurements - Washington, DC, USA
Duration: Jul 6 1998Jul 10 1998

Other

OtherProceedings of the 1998 Conference Precision Electromagnetic Measurements
CityWashington, DC, USA
Period7/6/987/10/98

Fingerprint

Semiconductor lasers
Spectrometers
semiconductor lasers
Pumps
spectrometers
pumps
Radiation
cavities
radiation

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Instrumentation

Cite this

Kaing, T., Lee, D., & Zondy, J. J. (1998). All-diode-laser based, dual-cavity AgGaS2 difference-frequency spectrometer for the 9-11 μm range. In T. L. Nelson (Ed.), CPEM Digest (Conference on Precision Electromagnetic Measurements) (pp. 157-158). IEEE.

All-diode-laser based, dual-cavity AgGaS2 difference-frequency spectrometer for the 9-11 μm range. / Kaing, T.; Lee, D.; Zondy, J. J.

CPEM Digest (Conference on Precision Electromagnetic Measurements). ed. / T.L. Nelson. IEEE, 1998. p. 157-158.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Kaing, T, Lee, D & Zondy, JJ 1998, All-diode-laser based, dual-cavity AgGaS2 difference-frequency spectrometer for the 9-11 μm range. in TL Nelson (ed.), CPEM Digest (Conference on Precision Electromagnetic Measurements). IEEE, pp. 157-158, Proceedings of the 1998 Conference Precision Electromagnetic Measurements, Washington, DC, USA, 7/6/98.
Kaing T, Lee D, Zondy JJ. All-diode-laser based, dual-cavity AgGaS2 difference-frequency spectrometer for the 9-11 μm range. In Nelson TL, editor, CPEM Digest (Conference on Precision Electromagnetic Measurements). IEEE. 1998. p. 157-158
Kaing, T. ; Lee, D. ; Zondy, J. J. / All-diode-laser based, dual-cavity AgGaS2 difference-frequency spectrometer for the 9-11 μm range. CPEM Digest (Conference on Precision Electromagnetic Measurements). editor / T.L. Nelson. IEEE, 1998. pp. 157-158
@inproceedings{50070973fccd465b842e5f3cf4764869,
title = "All-diode-laser based, dual-cavity AgGaS2 difference-frequency spectrometer for the 9-11 μm range",
abstract = "We report on preliminary performance of a mid-IR doubly-resonant difference frequency (DFG) spectrometer generating 30 nW of 10.2-μm tunable radiation out of 7 mW and 275 mW of the diode laser pump inputs at 778 nm and 842 nm.",
author = "T. Kaing and D. Lee and Zondy, {J. J.}",
year = "1998",
language = "English",
pages = "157--158",
editor = "T.L. Nelson",
booktitle = "CPEM Digest (Conference on Precision Electromagnetic Measurements)",
publisher = "IEEE",

}

TY - GEN

T1 - All-diode-laser based, dual-cavity AgGaS2 difference-frequency spectrometer for the 9-11 μm range

AU - Kaing, T.

AU - Lee, D.

AU - Zondy, J. J.

PY - 1998

Y1 - 1998

N2 - We report on preliminary performance of a mid-IR doubly-resonant difference frequency (DFG) spectrometer generating 30 nW of 10.2-μm tunable radiation out of 7 mW and 275 mW of the diode laser pump inputs at 778 nm and 842 nm.

AB - We report on preliminary performance of a mid-IR doubly-resonant difference frequency (DFG) spectrometer generating 30 nW of 10.2-μm tunable radiation out of 7 mW and 275 mW of the diode laser pump inputs at 778 nm and 842 nm.

UR - http://www.scopus.com/inward/record.url?scp=0032288615&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032288615&partnerID=8YFLogxK

M3 - Conference contribution

SP - 157

EP - 158

BT - CPEM Digest (Conference on Precision Electromagnetic Measurements)

A2 - Nelson, T.L.

PB - IEEE

ER -