Experimental study of a gas-liquid cylindrical cyclone separator performance

Antonio J. Meléndez-Ramírez, Miguel A. Reyes-Gutiérrez, Luis R. Rojas-Solórzano, Juan C. Marín-Moreno, José Colmenares

Research output: Contribution to journalConference articlepeer-review

5 Citations (Scopus)

Abstract

New data of the experimental performance of a Gas-Liquid Cylindrical Cyclone (GLCC) separator are presented. The data were collected using a 2 3/4" (0.07m) ID GLCC model working with an air-glycerin mixture. The inlet liquid flow rate, the inlet gas flow rate, the tangential liquid velocity inside the separator body and the gas carry under were measured for an operation regime without liquid carry over. The influence of the first three parameters over the gas carry under was established. Results show the separator efficiency is mainly affected by the inlet gas flow rate for the explored conditions with slug flow at the GLCC entrance.

Original languageEnglish
Article numberIMECE2004-62367
Pages (from-to)755-761
Number of pages7
JournalAmerican Society of Mechanical Engineers, Fluids Engineering Division (Publication) FED
Volume260
DOIs
Publication statusPublished - Dec 1 2004
Event2004 ASME International Mechanical Engineering Congress and Exposition, IMECE 2004 - Anaheim, CA, United States
Duration: Nov 13 2004Nov 19 2004

ASJC Scopus subject areas

  • General Engineering

Fingerprint

Dive into the research topics of 'Experimental study of a gas-liquid cylindrical cyclone separator performance'. Together they form a unique fingerprint.