The paper discusses the possibility to extract the most relevant active fiber parameters from the thresholds of fiber lasers built using spans of the fiber under test. This approach has been developed to allow designing high performance fibers laser with more specific and reliable data than those available in the literature for generic fibers, overcoming practical limitations due to the typical lack of details provided by fiber manufactures. Preliminary results have confirmed the usefulness of the devised procedure, which allowed predicting the optimal length that minimizes the threshold in excellent agreement with experiments. An analysis of the impact of the uncertainty in the extracted parameters is also provided.

Original languageEnglish
Title of host publicationConference Record - IEEE Instrumentation and Measurement Technology Conference
Pages664-669
Number of pages6
DOIs
Publication statusPublished - 2011
Externally publishedYes
Event2011 IEEE International Instrumentation and Measurement Technology Conference, I2MTC 2011 - Binjiang, Hangzhou, China
Duration: May 10 2011May 12 2011

Other

Other2011 IEEE International Instrumentation and Measurement Technology Conference, I2MTC 2011
CountryChina
CityBinjiang, Hangzhou
Period5/10/115/12/11

Fingerprint

Fiber lasers
Fibers
Experiments

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

Braglia, A., Neri, A., Perrone, G., Tosi, D., & Vallan, A. (2011). Indirect evaluation of active fiber parameters from the measurement of fiber laser threshold. In Conference Record - IEEE Instrumentation and Measurement Technology Conference (pp. 664-669). [5944138] https://doi.org/10.1109/IMTC.2011.5944138

Indirect evaluation of active fiber parameters from the measurement of fiber laser threshold. / Braglia, A.; Neri, A.; Perrone, G.; Tosi, D.; Vallan, A.

Conference Record - IEEE Instrumentation and Measurement Technology Conference. 2011. p. 664-669 5944138.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Braglia, A, Neri, A, Perrone, G, Tosi, D & Vallan, A 2011, Indirect evaluation of active fiber parameters from the measurement of fiber laser threshold. in Conference Record - IEEE Instrumentation and Measurement Technology Conference., 5944138, pp. 664-669, 2011 IEEE International Instrumentation and Measurement Technology Conference, I2MTC 2011, Binjiang, Hangzhou, China, 5/10/11. https://doi.org/10.1109/IMTC.2011.5944138
Braglia A, Neri A, Perrone G, Tosi D, Vallan A. Indirect evaluation of active fiber parameters from the measurement of fiber laser threshold. In Conference Record - IEEE Instrumentation and Measurement Technology Conference. 2011. p. 664-669. 5944138 https://doi.org/10.1109/IMTC.2011.5944138
Braglia, A. ; Neri, A. ; Perrone, G. ; Tosi, D. ; Vallan, A. / Indirect evaluation of active fiber parameters from the measurement of fiber laser threshold. Conference Record - IEEE Instrumentation and Measurement Technology Conference. 2011. pp. 664-669
@inproceedings{905747f44d2c4a63acadd879be78cc65,
title = "Indirect evaluation of active fiber parameters from the measurement of fiber laser threshold",
abstract = "The paper discusses the possibility to extract the most relevant active fiber parameters from the thresholds of fiber lasers built using spans of the fiber under test. This approach has been developed to allow designing high performance fibers laser with more specific and reliable data than those available in the literature for generic fibers, overcoming practical limitations due to the typical lack of details provided by fiber manufactures. Preliminary results have confirmed the usefulness of the devised procedure, which allowed predicting the optimal length that minimizes the threshold in excellent agreement with experiments. An analysis of the impact of the uncertainty in the extracted parameters is also provided.",
author = "A. Braglia and A. Neri and G. Perrone and D. Tosi and A. Vallan",
year = "2011",
doi = "10.1109/IMTC.2011.5944138",
language = "English",
isbn = "9781424479351",
pages = "664--669",
booktitle = "Conference Record - IEEE Instrumentation and Measurement Technology Conference",

}

TY - GEN

T1 - Indirect evaluation of active fiber parameters from the measurement of fiber laser threshold

AU - Braglia, A.

AU - Neri, A.

AU - Perrone, G.

AU - Tosi, D.

AU - Vallan, A.

PY - 2011

Y1 - 2011

N2 - The paper discusses the possibility to extract the most relevant active fiber parameters from the thresholds of fiber lasers built using spans of the fiber under test. This approach has been developed to allow designing high performance fibers laser with more specific and reliable data than those available in the literature for generic fibers, overcoming practical limitations due to the typical lack of details provided by fiber manufactures. Preliminary results have confirmed the usefulness of the devised procedure, which allowed predicting the optimal length that minimizes the threshold in excellent agreement with experiments. An analysis of the impact of the uncertainty in the extracted parameters is also provided.

AB - The paper discusses the possibility to extract the most relevant active fiber parameters from the thresholds of fiber lasers built using spans of the fiber under test. This approach has been developed to allow designing high performance fibers laser with more specific and reliable data than those available in the literature for generic fibers, overcoming practical limitations due to the typical lack of details provided by fiber manufactures. Preliminary results have confirmed the usefulness of the devised procedure, which allowed predicting the optimal length that minimizes the threshold in excellent agreement with experiments. An analysis of the impact of the uncertainty in the extracted parameters is also provided.

UR - http://www.scopus.com/inward/record.url?scp=80051886732&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80051886732&partnerID=8YFLogxK