We have measured the frequency of the He-Ne/I2 laser starting from the Cs referenced CO2/OsO4 laboratory standard. As the laser diode stabilized on the two-photon transition in Rb seems to be a suitable reference for spectroscopic studies (H, He...) and a promising standard, we are modifying our chain in order to measure frequencies around 780 nm and specially the Rb one.

Original languageEnglish
Title of host publicationCPEM Digest (Conference on Precision Electromagnetic Measurements)
PublisherIEEE
Pages325-326
Number of pages2
Publication statusPublished - 1994
Externally publishedYes
EventProceedings of the 1994 Conference on Precision Electromagnetic Measurements - Boulder, CO, USA
Duration: Jun 27 1994Jul 1 1994

Other

OtherProceedings of the 1994 Conference on Precision Electromagnetic Measurements
CityBoulder, CO, USA
Period6/27/947/1/94

Fingerprint

synthesis
Semiconductor lasers
Photons
Lasers
semiconductor lasers
photons
lasers

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Instrumentation

Cite this

Touahri, D., Zondy, J. J., Acef, O., Hilico, L., Nez, F., Clairon, A., ... Felder, R. (1994). LPTF frequency synthesis chain: Results and improvement for the near future. In CPEM Digest (Conference on Precision Electromagnetic Measurements) (pp. 325-326). IEEE.

LPTF frequency synthesis chain : Results and improvement for the near future. / Touahri, D.; Zondy, J. J.; Acef, O.; Hilico, L.; Nez, F.; Clairon, A.; Millerioux, Y.; Biraben, F.; Julien, L.; Felder, R.

CPEM Digest (Conference on Precision Electromagnetic Measurements). IEEE, 1994. p. 325-326.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Touahri, D, Zondy, JJ, Acef, O, Hilico, L, Nez, F, Clairon, A, Millerioux, Y, Biraben, F, Julien, L & Felder, R 1994, LPTF frequency synthesis chain: Results and improvement for the near future. in CPEM Digest (Conference on Precision Electromagnetic Measurements). IEEE, pp. 325-326, Proceedings of the 1994 Conference on Precision Electromagnetic Measurements, Boulder, CO, USA, 6/27/94.
Touahri D, Zondy JJ, Acef O, Hilico L, Nez F, Clairon A et al. LPTF frequency synthesis chain: Results and improvement for the near future. In CPEM Digest (Conference on Precision Electromagnetic Measurements). IEEE. 1994. p. 325-326
Touahri, D. ; Zondy, J. J. ; Acef, O. ; Hilico, L. ; Nez, F. ; Clairon, A. ; Millerioux, Y. ; Biraben, F. ; Julien, L. ; Felder, R. / LPTF frequency synthesis chain : Results and improvement for the near future. CPEM Digest (Conference on Precision Electromagnetic Measurements). IEEE, 1994. pp. 325-326
@inproceedings{38e18d7324f64a08b7b76bfc72f63998,
title = "LPTF frequency synthesis chain: Results and improvement for the near future",
abstract = "We have measured the frequency of the He-Ne/I2 laser starting from the Cs referenced CO2/OsO4 laboratory standard. As the laser diode stabilized on the two-photon transition in Rb seems to be a suitable reference for spectroscopic studies (H, He...) and a promising standard, we are modifying our chain in order to measure frequencies around 780 nm and specially the Rb one.",
author = "D. Touahri and Zondy, {J. J.} and O. Acef and L. Hilico and F. Nez and A. Clairon and Y. Millerioux and F. Biraben and L. Julien and R. Felder",
year = "1994",
language = "English",
pages = "325--326",
booktitle = "CPEM Digest (Conference on Precision Electromagnetic Measurements)",
publisher = "IEEE",

}

TY - GEN

T1 - LPTF frequency synthesis chain

T2 - Results and improvement for the near future

AU - Touahri, D.

AU - Zondy, J. J.

AU - Acef, O.

AU - Hilico, L.

AU - Nez, F.

AU - Clairon, A.

AU - Millerioux, Y.

AU - Biraben, F.

AU - Julien, L.

AU - Felder, R.

PY - 1994

Y1 - 1994

N2 - We have measured the frequency of the He-Ne/I2 laser starting from the Cs referenced CO2/OsO4 laboratory standard. As the laser diode stabilized on the two-photon transition in Rb seems to be a suitable reference for spectroscopic studies (H, He...) and a promising standard, we are modifying our chain in order to measure frequencies around 780 nm and specially the Rb one.

AB - We have measured the frequency of the He-Ne/I2 laser starting from the Cs referenced CO2/OsO4 laboratory standard. As the laser diode stabilized on the two-photon transition in Rb seems to be a suitable reference for spectroscopic studies (H, He...) and a promising standard, we are modifying our chain in order to measure frequencies around 780 nm and specially the Rb one.

UR - http://www.scopus.com/inward/record.url?scp=0028555967&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028555967&partnerID=8YFLogxK

M3 - Conference contribution

SP - 325

EP - 326

BT - CPEM Digest (Conference on Precision Electromagnetic Measurements)

PB - IEEE

ER -