Percutaneous management of a chronic post-transplant ureteral leak. Report of a case

Hans O. Leven, Elijah O. Kehinde

Research output: Contribution to journalArticle

Abstract

We report a case where a 14-F (4.7 mm) polyurethane nephrostomy catheter (William Cook, Europe) was used successfully as an external/internal stent for sealing a chronic post-transplant ureteral leak.

Original languageEnglish
Pages (from-to)99-101
Number of pages3
JournalScandinavian Journal of Urology and Nephrology
Volume31
Issue number1
Publication statusPublished - 1997
Externally publishedYes

Fingerprint

Polyurethanes
Stents
Catheters
Transplants

Keywords

  • catheters and catheterization technology
  • fistula urinary
  • interventional procedure
  • ureter

ASJC Scopus subject areas

  • Nephrology
  • Urology

Cite this

Percutaneous management of a chronic post-transplant ureteral leak. Report of a case. / Leven, Hans O.; Kehinde, Elijah O.

In: Scandinavian Journal of Urology and Nephrology, Vol. 31, No. 1, 1997, p. 99-101.

Research output: Contribution to journalArticle

@article{375cafda7cf142eabc80a9ad0adc05c5,
title = "Percutaneous management of a chronic post-transplant ureteral leak. Report of a case",
abstract = "We report a case where a 14-F (4.7 mm) polyurethane nephrostomy catheter (William Cook, Europe) was used successfully as an external/internal stent for sealing a chronic post-transplant ureteral leak.",
keywords = "catheters and catheterization technology, fistula urinary, interventional procedure, ureter",
author = "Leven, {Hans O.} and Kehinde, {Elijah O.}",
year = "1997",
language = "English",
volume = "31",
pages = "99--101",
journal = "Scandinavian Journal of Urology",
issn = "2168-1805",
publisher = "Informa Healthcare",
number = "1",

}

TY - JOUR

T1 - Percutaneous management of a chronic post-transplant ureteral leak. Report of a case

AU - Leven, Hans O.

AU - Kehinde, Elijah O.

PY - 1997

Y1 - 1997

N2 - We report a case where a 14-F (4.7 mm) polyurethane nephrostomy catheter (William Cook, Europe) was used successfully as an external/internal stent for sealing a chronic post-transplant ureteral leak.

AB - We report a case where a 14-F (4.7 mm) polyurethane nephrostomy catheter (William Cook, Europe) was used successfully as an external/internal stent for sealing a chronic post-transplant ureteral leak.

KW - catheters and catheterization technology

KW - fistula urinary

KW - interventional procedure

KW - ureter

UR - http://www.scopus.com/inward/record.url?scp=0031056357&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031056357&partnerID=8YFLogxK

M3 - Article

VL - 31

SP - 99

EP - 101

JO - Scandinavian Journal of Urology

JF - Scandinavian Journal of Urology

SN - 2168-1805

IS - 1

ER -