Reliability analysis of Finometer and AGE-Reader devices in a clinical research trial

Anna Deltsidou, Vasilios Zarikas, Dimos Mastrogiannis, Eleni Kapreli, Dimitrios Bourdas, Elpiniki Papageorgiou, Vasilios Raftopoulos, Maria Noula, Maria Lambadiari, Katerina Lykeridou

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Fundamental issues emerging from the widespread use of noninvasive techniques in healthcare sciences' research are the reliability and validity. This work presents the reliability analysis of a clinical trial that uses a Finometer and an AGE Reader. The aim is to provide a self-consistent and meaningful reliability analysis concerning Finometer and AGE-Reader devices, something that is often missing in the research field of healthcare sciences and present results could be used to fill up this gap. Since four raters are used for taking measurements in this study, the presented reliability analysis includes tests for the raters as well as for the instruments' internal consistency of the instruments. It was found that both the reported inter-rater reliability and instruments' reliability of internal consistency were found adequately high. In conclusion, Finometer and AGE-Reader devices showed high reliability and the present results can be used as a concrete basis for future studies utilising these devices.

Original languageEnglish
Pages (from-to)78-96
Number of pages19
JournalInternational Journal of Reliability and Safety
Volume11
Issue number1-2
DOIs
Publication statusPublished - Jan 1 2017

Fingerprint

Reliability analysis
Concretes

Keywords

  • AGE Reader
  • Analysis
  • Finometer
  • Internal consistency.
  • Reliability

ASJC Scopus subject areas

  • Safety, Risk, Reliability and Quality

Cite this

Deltsidou, A., Zarikas, V., Mastrogiannis, D., Kapreli, E., Bourdas, D., Papageorgiou, E., ... Lykeridou, K. (2017). Reliability analysis of Finometer and AGE-Reader devices in a clinical research trial. International Journal of Reliability and Safety, 11(1-2), 78-96. https://doi.org/10.1504/IJRS.2017.088550

Reliability analysis of Finometer and AGE-Reader devices in a clinical research trial. / Deltsidou, Anna; Zarikas, Vasilios; Mastrogiannis, Dimos; Kapreli, Eleni; Bourdas, Dimitrios; Papageorgiou, Elpiniki; Raftopoulos, Vasilios; Noula, Maria; Lambadiari, Maria; Lykeridou, Katerina.

In: International Journal of Reliability and Safety, Vol. 11, No. 1-2, 01.01.2017, p. 78-96.

Research output: Contribution to journalArticle

Deltsidou, A, Zarikas, V, Mastrogiannis, D, Kapreli, E, Bourdas, D, Papageorgiou, E, Raftopoulos, V, Noula, M, Lambadiari, M & Lykeridou, K 2017, 'Reliability analysis of Finometer and AGE-Reader devices in a clinical research trial', International Journal of Reliability and Safety, vol. 11, no. 1-2, pp. 78-96. https://doi.org/10.1504/IJRS.2017.088550
Deltsidou, Anna ; Zarikas, Vasilios ; Mastrogiannis, Dimos ; Kapreli, Eleni ; Bourdas, Dimitrios ; Papageorgiou, Elpiniki ; Raftopoulos, Vasilios ; Noula, Maria ; Lambadiari, Maria ; Lykeridou, Katerina. / Reliability analysis of Finometer and AGE-Reader devices in a clinical research trial. In: International Journal of Reliability and Safety. 2017 ; Vol. 11, No. 1-2. pp. 78-96.
@article{fc4b1835f5ec4932808c935478ab0701,
title = "Reliability analysis of Finometer and AGE-Reader devices in a clinical research trial",
abstract = "Fundamental issues emerging from the widespread use of noninvasive techniques in healthcare sciences' research are the reliability and validity. This work presents the reliability analysis of a clinical trial that uses a Finometer and an AGE Reader. The aim is to provide a self-consistent and meaningful reliability analysis concerning Finometer and AGE-Reader devices, something that is often missing in the research field of healthcare sciences and present results could be used to fill up this gap. Since four raters are used for taking measurements in this study, the presented reliability analysis includes tests for the raters as well as for the instruments' internal consistency of the instruments. It was found that both the reported inter-rater reliability and instruments' reliability of internal consistency were found adequately high. In conclusion, Finometer and AGE-Reader devices showed high reliability and the present results can be used as a concrete basis for future studies utilising these devices.",
keywords = "AGE Reader, Analysis, Finometer, Internal consistency., Reliability",
author = "Anna Deltsidou and Vasilios Zarikas and Dimos Mastrogiannis and Eleni Kapreli and Dimitrios Bourdas and Elpiniki Papageorgiou and Vasilios Raftopoulos and Maria Noula and Maria Lambadiari and Katerina Lykeridou",
year = "2017",
month = "1",
day = "1",
doi = "10.1504/IJRS.2017.088550",
language = "English",
volume = "11",
pages = "78--96",
journal = "International Journal of Reliability and Safety",
issn = "1479-389X",
publisher = "Inderscience Enterprises Ltd",
number = "1-2",

}

TY - JOUR

T1 - Reliability analysis of Finometer and AGE-Reader devices in a clinical research trial

AU - Deltsidou, Anna

AU - Zarikas, Vasilios

AU - Mastrogiannis, Dimos

AU - Kapreli, Eleni

AU - Bourdas, Dimitrios

AU - Papageorgiou, Elpiniki

AU - Raftopoulos, Vasilios

AU - Noula, Maria

AU - Lambadiari, Maria

AU - Lykeridou, Katerina

PY - 2017/1/1

Y1 - 2017/1/1

N2 - Fundamental issues emerging from the widespread use of noninvasive techniques in healthcare sciences' research are the reliability and validity. This work presents the reliability analysis of a clinical trial that uses a Finometer and an AGE Reader. The aim is to provide a self-consistent and meaningful reliability analysis concerning Finometer and AGE-Reader devices, something that is often missing in the research field of healthcare sciences and present results could be used to fill up this gap. Since four raters are used for taking measurements in this study, the presented reliability analysis includes tests for the raters as well as for the instruments' internal consistency of the instruments. It was found that both the reported inter-rater reliability and instruments' reliability of internal consistency were found adequately high. In conclusion, Finometer and AGE-Reader devices showed high reliability and the present results can be used as a concrete basis for future studies utilising these devices.

AB - Fundamental issues emerging from the widespread use of noninvasive techniques in healthcare sciences' research are the reliability and validity. This work presents the reliability analysis of a clinical trial that uses a Finometer and an AGE Reader. The aim is to provide a self-consistent and meaningful reliability analysis concerning Finometer and AGE-Reader devices, something that is often missing in the research field of healthcare sciences and present results could be used to fill up this gap. Since four raters are used for taking measurements in this study, the presented reliability analysis includes tests for the raters as well as for the instruments' internal consistency of the instruments. It was found that both the reported inter-rater reliability and instruments' reliability of internal consistency were found adequately high. In conclusion, Finometer and AGE-Reader devices showed high reliability and the present results can be used as a concrete basis for future studies utilising these devices.

KW - AGE Reader

KW - Analysis

KW - Finometer

KW - Internal consistency.

KW - Reliability

UR - http://www.scopus.com/inward/record.url?scp=85042602056&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85042602056&partnerID=8YFLogxK

U2 - 10.1504/IJRS.2017.088550

DO - 10.1504/IJRS.2017.088550

M3 - Article

VL - 11

SP - 78

EP - 96

JO - International Journal of Reliability and Safety

JF - International Journal of Reliability and Safety

SN - 1479-389X

IS - 1-2

ER -