TY - JOUR
T1 - Ultrasensitive fluorescent carbon dot sensor for quantification of soluble and insoluble Cr(VI) in particulate matter
AU - Adotey, Enoch Kwasi
AU - Amouei Torkmahalleh, Mehdi
AU - Tastanova, Lyazzat
AU - Bekeshev, Amirbek
AU - Shah, Dhawal
AU - Hopke, Philip K.
AU - Lee, Woojin
AU - Balanay, Mannix P.
N1 - Publisher Copyright:
© 2023 Elsevier B.V.
PY - 2024/1/15
Y1 - 2024/1/15
N2 - This study investigates advanced functional materials to address the need for practical and affordable analytical techniques for monitoring large amounts of insoluble Cr(VI). N,S-doped fluorescent carbon dots (f-CDs) were fabricated through microwave synthesis, with an average diameter of 10 nm. These f-CDs were explored as potential sensors for detecting Cr(VI) in ambient particulate matter (PM). Laboratory experiments yielded positive results, showing average recoveries of 106.0%, 102.3%, 96.4%, and 101.7% for PbCrO4, BaCrO4, CaCrO4, and (NH4)2CrO4, respectively. Applying the fluorescence method to field PM samples, a method detection limit (MDL) of 0.32 ng/m3 for total Cr(VI) quantification was achieved. The fluorescence decay of carbon dots remained stable over time, suggesting that Cr(VI) quenching primarily occurred due to the internal filter effect through a static quenching mechanism. These f-CDs exhibited advantageous properties, including affordability, solubility, luminescence, and sensitivity, positioning them as a promising alternative for Cr(VI) detection in ambient air particulates. This study contributes to further developing carbon-based functional materials for detecting metallic air pollutants.
AB - This study investigates advanced functional materials to address the need for practical and affordable analytical techniques for monitoring large amounts of insoluble Cr(VI). N,S-doped fluorescent carbon dots (f-CDs) were fabricated through microwave synthesis, with an average diameter of 10 nm. These f-CDs were explored as potential sensors for detecting Cr(VI) in ambient particulate matter (PM). Laboratory experiments yielded positive results, showing average recoveries of 106.0%, 102.3%, 96.4%, and 101.7% for PbCrO4, BaCrO4, CaCrO4, and (NH4)2CrO4, respectively. Applying the fluorescence method to field PM samples, a method detection limit (MDL) of 0.32 ng/m3 for total Cr(VI) quantification was achieved. The fluorescence decay of carbon dots remained stable over time, suggesting that Cr(VI) quenching primarily occurred due to the internal filter effect through a static quenching mechanism. These f-CDs exhibited advantageous properties, including affordability, solubility, luminescence, and sensitivity, positioning them as a promising alternative for Cr(VI) detection in ambient air particulates. This study contributes to further developing carbon-based functional materials for detecting metallic air pollutants.
KW - Air Quality
KW - Insoluble chromium
KW - Luminescence, Sensors
KW - Particulate matter
UR - http://www.scopus.com/inward/record.url?scp=85173627062&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85173627062&partnerID=8YFLogxK
U2 - 10.1016/j.jhazmat.2023.132671
DO - 10.1016/j.jhazmat.2023.132671
M3 - Article
C2 - 37827102
AN - SCOPUS:85173627062
SN - 0304-3894
VL - 462
JO - Journal of Hazardous Materials
JF - Journal of Hazardous Materials
M1 - 132671
ER -