Ultrasonic evaluation of the combined effect of corrosion and overheating in grade 20 steel water-wall boiler tubes

S. Kapayeva, M. J. Bergander, A. Vakhguelt, S. I. Khairaliyev

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Boilers are the most troublesome components of electric power, chemical and processing plants, generating high costs in unscheduled shutdowns, repairs and power replacement. Every occurrence of ruptured tubes leads to emergency shutdown of the entire plant. Past data show that a combination of wall thinning and overheating (creep) is a major damage mechanism contributing to the failure of boiler tubes. This paper describes a joint international effort to demonstrate the value of non-destructive testing (NDT) in evaluating the condition of a boiler. The main question is how to treat the combined effect of overheating and wall thinning, which determines the way NDT results are utilised. There is a broad literature base dealing with this problem as well as guidelines (for example from the Electric Power Research Institute (EPRI)), but they mainly pertain to low-alloy steels, such as chromium-molybdenum (Cr-Mo), which are prevalent in boilers used in most Western countries. However, the research described here concentrates on Central Asian locations, where the majority of furnace tubes are made of grade 20 steel. This paper attempts to develop recommendations for the combined treatment of different types of tube degradation in low-carbon steel boiler tubes, whereas existing reject/removal criteria treat each damage mechanism separately. The method described for predicting the remaining tube life is based on using two NDT ultrasonic techniques: electromagnetic acoustic transducer (EMAT) for wall thickness measurement and specialised ultrasonic testing (UT) to detect internal oxide scale. It is concluded that NDT methods offer an attractive solution to remaining life assessment (RLA) in power boilers due to their ability to accurately determine wall thickness and hoop stress in tubes and to indirectly detect the degree of overheating by measurement of the internal oxide thickness.

Original languageEnglish
Pages (from-to)637-643
Number of pages7
JournalInsight: Non-Destructive Testing and Condition Monitoring
Volume59
Issue number12
DOIs
Publication statusPublished - Dec 1 2017

Fingerprint

Steel
Boilers
Ultrasonics
Corrosion
Nondestructive examination
Water
Oxides
Acoustic transducers
Ultrasonic testing
Thickness measurement
Molybdenum
Low carbon steel
Chromium
High strength steel
Creep
Furnaces
Repair
Degradation
Processing
Costs

ASJC Scopus subject areas

  • Mechanics of Materials
  • Mechanical Engineering
  • Metals and Alloys
  • Materials Chemistry

Cite this

Ultrasonic evaluation of the combined effect of corrosion and overheating in grade 20 steel water-wall boiler tubes. / Kapayeva, S.; Bergander, M. J.; Vakhguelt, A.; Khairaliyev, S. I.

In: Insight: Non-Destructive Testing and Condition Monitoring, Vol. 59, No. 12, 01.12.2017, p. 637-643.

Research output: Contribution to journalArticle

Kapayeva, S. ; Bergander, M. J. ; Vakhguelt, A. ; Khairaliyev, S. I. / Ultrasonic evaluation of the combined effect of corrosion and overheating in grade 20 steel water-wall boiler tubes. In: Insight: Non-Destructive Testing and Condition Monitoring. 2017 ; Vol. 59, No. 12. pp. 637-643.
@article{0a06c387c369403381c4b5c7b3589a72,
title = "Ultrasonic evaluation of the combined effect of corrosion and overheating in grade 20 steel water-wall boiler tubes",
abstract = "Boilers are the most troublesome components of electric power, chemical and processing plants, generating high costs in unscheduled shutdowns, repairs and power replacement. Every occurrence of ruptured tubes leads to emergency shutdown of the entire plant. Past data show that a combination of wall thinning and overheating (creep) is a major damage mechanism contributing to the failure of boiler tubes. This paper describes a joint international effort to demonstrate the value of non-destructive testing (NDT) in evaluating the condition of a boiler. The main question is how to treat the combined effect of overheating and wall thinning, which determines the way NDT results are utilised. There is a broad literature base dealing with this problem as well as guidelines (for example from the Electric Power Research Institute (EPRI)), but they mainly pertain to low-alloy steels, such as chromium-molybdenum (Cr-Mo), which are prevalent in boilers used in most Western countries. However, the research described here concentrates on Central Asian locations, where the majority of furnace tubes are made of grade 20 steel. This paper attempts to develop recommendations for the combined treatment of different types of tube degradation in low-carbon steel boiler tubes, whereas existing reject/removal criteria treat each damage mechanism separately. The method described for predicting the remaining tube life is based on using two NDT ultrasonic techniques: electromagnetic acoustic transducer (EMAT) for wall thickness measurement and specialised ultrasonic testing (UT) to detect internal oxide scale. It is concluded that NDT methods offer an attractive solution to remaining life assessment (RLA) in power boilers due to their ability to accurately determine wall thickness and hoop stress in tubes and to indirectly detect the degree of overheating by measurement of the internal oxide thickness.",
author = "S. Kapayeva and Bergander, {M. J.} and A. Vakhguelt and Khairaliyev, {S. I.}",
year = "2017",
month = "12",
day = "1",
doi = "10.1784/insi.2017.59.12.637",
language = "English",
volume = "59",
pages = "637--643",
journal = "Insight: Non-Destructive Testing and Condition Monitoring",
issn = "1354-2575",
publisher = "British Institute of Non-Destructive Testing",
number = "12",

}

TY - JOUR

T1 - Ultrasonic evaluation of the combined effect of corrosion and overheating in grade 20 steel water-wall boiler tubes

AU - Kapayeva, S.

AU - Bergander, M. J.

AU - Vakhguelt, A.

AU - Khairaliyev, S. I.

PY - 2017/12/1

Y1 - 2017/12/1

N2 - Boilers are the most troublesome components of electric power, chemical and processing plants, generating high costs in unscheduled shutdowns, repairs and power replacement. Every occurrence of ruptured tubes leads to emergency shutdown of the entire plant. Past data show that a combination of wall thinning and overheating (creep) is a major damage mechanism contributing to the failure of boiler tubes. This paper describes a joint international effort to demonstrate the value of non-destructive testing (NDT) in evaluating the condition of a boiler. The main question is how to treat the combined effect of overheating and wall thinning, which determines the way NDT results are utilised. There is a broad literature base dealing with this problem as well as guidelines (for example from the Electric Power Research Institute (EPRI)), but they mainly pertain to low-alloy steels, such as chromium-molybdenum (Cr-Mo), which are prevalent in boilers used in most Western countries. However, the research described here concentrates on Central Asian locations, where the majority of furnace tubes are made of grade 20 steel. This paper attempts to develop recommendations for the combined treatment of different types of tube degradation in low-carbon steel boiler tubes, whereas existing reject/removal criteria treat each damage mechanism separately. The method described for predicting the remaining tube life is based on using two NDT ultrasonic techniques: electromagnetic acoustic transducer (EMAT) for wall thickness measurement and specialised ultrasonic testing (UT) to detect internal oxide scale. It is concluded that NDT methods offer an attractive solution to remaining life assessment (RLA) in power boilers due to their ability to accurately determine wall thickness and hoop stress in tubes and to indirectly detect the degree of overheating by measurement of the internal oxide thickness.

AB - Boilers are the most troublesome components of electric power, chemical and processing plants, generating high costs in unscheduled shutdowns, repairs and power replacement. Every occurrence of ruptured tubes leads to emergency shutdown of the entire plant. Past data show that a combination of wall thinning and overheating (creep) is a major damage mechanism contributing to the failure of boiler tubes. This paper describes a joint international effort to demonstrate the value of non-destructive testing (NDT) in evaluating the condition of a boiler. The main question is how to treat the combined effect of overheating and wall thinning, which determines the way NDT results are utilised. There is a broad literature base dealing with this problem as well as guidelines (for example from the Electric Power Research Institute (EPRI)), but they mainly pertain to low-alloy steels, such as chromium-molybdenum (Cr-Mo), which are prevalent in boilers used in most Western countries. However, the research described here concentrates on Central Asian locations, where the majority of furnace tubes are made of grade 20 steel. This paper attempts to develop recommendations for the combined treatment of different types of tube degradation in low-carbon steel boiler tubes, whereas existing reject/removal criteria treat each damage mechanism separately. The method described for predicting the remaining tube life is based on using two NDT ultrasonic techniques: electromagnetic acoustic transducer (EMAT) for wall thickness measurement and specialised ultrasonic testing (UT) to detect internal oxide scale. It is concluded that NDT methods offer an attractive solution to remaining life assessment (RLA) in power boilers due to their ability to accurately determine wall thickness and hoop stress in tubes and to indirectly detect the degree of overheating by measurement of the internal oxide thickness.

UR - http://www.scopus.com/inward/record.url?scp=85038395124&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85038395124&partnerID=8YFLogxK

U2 - 10.1784/insi.2017.59.12.637

DO - 10.1784/insi.2017.59.12.637

M3 - Article

VL - 59

SP - 637

EP - 643

JO - Insight: Non-Destructive Testing and Condition Monitoring

JF - Insight: Non-Destructive Testing and Condition Monitoring

SN - 1354-2575

IS - 12

ER -